Forensis Solutions For Energy Systems
Ankara, Türkiye Energy system measurement and analysis
TR EN

The meter shows what you pay. We measure why you pay it.

A compressed air leak, harmonic distortion, a dead battery cell. We measure what is costing you money, work out what it costs per year, and write down how to fix it — in one report.

01Company

We make the invisible measurable.

In any plant, the most expensive faults are usually the quietest ones. A busbar connection runs hot for months, a compressor works for nothing, a UPS battery dies. None of them raise an alarm; all of them eventually turn into an invoice or an unplanned stoppage. Forensis measures them on site and turns them into a report you can act on.


03
Core services
IEC
Reference standards
TR/EN
Report language
  • 01Measurement on site

    From compressed air lines to switchboards and UPS battery strings, we measure while your plant is running.

  • 02A defensible report

    Every finding comes with the instrument identity, calibration record and measurement conditions. You can hand it to an insurer or an auditor.

  • 03Output you can decide on

    The report does not stop at “there is a problem”. It states the root cause, the annual cost and the workable options. The quotation is a separate document.

02Services

Three services, three concrete reports.

Each one addresses a specific problem in your plant and ends with a report you can read and share. Taking one does not commit you to the others.

Compressed air leak detection
01

FOR AirScan

Compressed air leak detection

We walk the plant with an ultrasonic detector. We find the leaks, photograph them, tag them, and work out what each one costs per year. Production does not stop; in most plants it is done in a single visit.

OutputForensis Compressed Air Loss Report

Single visitNo shutdownEstimated loss
Power quality measurement
02

FOR PowerCheck

Power quality measurement

We leave a network analyser on site and record for one to two weeks: THD, harmonic spectrum, dips and swells, transients, phase imbalance, power factor and load profile. We find which load the distortion comes from.

OutputForensis Electrical Health Report

IEC 61000-4-30 Class A/SIEC 625867–14 days
UPS and critical battery testing
03

FOR BatteryCheck

UPS and critical battery testing

We test the string cell by cell: voltage, internal resistance, temperature and imbalance. Your UPS may look like it is working; the dead cell inside it only shows up when you measure.

OutputForensis Battery Health Report

Cell-level testingPeriodic checksCritical infrastructure

03Problems

Situations you will recognise

Each row below pairs a situation we meet often in the field with what Forensis does about it.

Problem What it costs Forensis answer
01Reactive energy charge Once the limit is exceeded, reactive consumption appears on the bill PowerCheck + compensation and filter analysis
02Harmonic distortion Transformer heating, equipment failure, early compensation failure PowerCheck + filter assessment
03Compressed air leaks Continuous energy loss, compressor running for nothing AirScan leak map and repair priority list
04Hot panels and connections Fire risk, unplanned stoppage, insurance exposure Thermal survey and monitoring proposal
05UPS battery failure Unexpected outage under critical load BatteryCheck cell health report
06Energy management obligations Audit and declaration requirements above 1,000 TOE Measurement and data infrastructure support
07Carbon data for export Buyers asking for verified energy and emission data Energy and emission measurement infrastructure
08MV insulation degradation Major failure risk, extended downtime Partial discharge measurement (advanced capability)

04Method

Trust comes from the measurement chain, not the instrument brand.

Anyone can buy the same class of instrument. The difference is whether the calibration is traceable, whether the report is written to the same discipline every time, and whether the result stands up in front of a third party.

Our commitment

Our measurement rests on traceable calibration, our report follows a standard format, and our findings are defensible to a third party.

  • 01

    Traceable calibration

    Every instrument we use goes to site under a traceable calibration certificate. Serial number, calibration date and stated uncertainty appear in the report.

  • 02

    Standard report

    Measurement conditions, connection method and procedure appear in the same place in every report. Nobody has to hunt for how something was measured.

  • 03

    Report and quotation are separate

    Findings come in a neutral report. If you want a quotation it arrives later, as its own document. You do not have to buy anything from us to keep the report.

The promise is not “we have the instrument” — it is “the entire measurement chain is documented”.

05Process

A clear path from site to decision

Each step builds on the one before it. You see what we measured at every stage and why it mattered.

  1. 01 Diagnose

    Measure

    We come to the site and measure under real operating conditions.


    Field work

  2. 02 Identify

    Diagnose

    We find not what the problem is, but why it is happening.


    Analysis

  3. 03 Quantify

    Impact

    We work out the annual cost, the risk and the likelihood of downtime.


    Quantification

  4. 04 Solve

    Solution

    We set out workable options with their relative merits.


    Engineering

  5. 05 Monitor

    Monitor

    For recurring problems we install continuous monitoring. If it does not recur, we do not.


    Continuity

06Capability

What we offer today and what we are adding

Active services

Ready on site


  • FOR AirScan — compressed air leak detection
  • FOR PowerCheck — power quality measurement
  • FOR BatteryCheck — critical battery health

Expanding

Thermal and environment


  • Thermal camera survey
  • Continuous thermal monitoring
  • Switchroom environment monitoring

Advanced analysis

Deep diagnostics


  • Partial discharge (PD) measurement
  • Energy and emission data infrastructure
  • Motor current signature analysis (MCSA)

07Contact

Let's talk about your plant.

The first step is a site measurement and a clear report. If you have not settled on what you need yet, write anyway — we will work out together which measurement is worth doing.


  • The report presents findings neutrally; the quotation comes separately.
  • Measurements are taken with traceably calibrated instruments.
  • Reporting is available in Turkish and English.